Location: City of Wyoming Clean Water Plant  |  Wyoming, Michigan  
Plant Size: 90 MGD  
Installation: 2019 (1) THK350 Sludge Thickener

OPERATING DATA

- Feed @ 0.6-1.2% TS
- 240 gpm average
- 95% capture
- <1 lb/ton polymer, active
- <0.12 kW/gpm
- 6.5% TS TWAS

PROBLEM

Two aging Bird 5100 modified dewatering centrifuges were needed to thicken WAS sludge to a total flow of 240 gpm. Each of the older Bird centrifuges operated at 80 kWh with a flow of 120 gpm. The large, accelerated mass and the relatively low flow rate of each unit were the primary sources for the plant’s high power consumption.

<https://www.centrisys-cnp.com/hs/cta/wi/redirect?encryptedPayload=AVxigLI5%2FJ4KlbDVOCvSEEb6CqfdZjC2gEgtkAnvvKTsHNtPuF5eUS3J%2FpEIcrVH67cU3Z%2Byzjg%2BuMoAjsvozCtniwn7lteSjFzp98Rob4Ld2ry%2FczaXa3cKhHZs4ZJCRWl%2FlnalunamKb3n14yLYrx38M3I%2FA4nZTJAR54IoegZ7RcCwVYTnIGxRsdCYxuxBgcM7Z6B3YD%2Bjk6RV5u8cxGdHEbw3l8puvo83PuA0vpsfyNR&webInteractiveContentId=212885590354&portalId=4299619>

RESULTS

- Installation of one THK350 replaced two large Bird 5100 centrifuges
- Awarded an energy reduction grant due to the 75% power reduction, saving up to $88,300/yr ($0.08 kW/h)
- Solids discharge controlled for either off-site or land application via the patented hydro-pneumatic air which further fine-tunes the sludge control 
    - 3.5-4.5% TS for off-site pumping
    - 5.5-6.5% TS for land application

 

[View full post](https://www.centrisys-cnp.com/case-studies/plant-replaces-modified-dewatering-centrifuges-with-sludge-thickening-centrifuges)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Sample HubSpot User"
  },
  "dateModified" : "2026-05-19T19:09:37.769Z",
  "datePublished" : "2022-07-05T21:21:23Z",
  "headline" : "Plant Replaces Modified Dewatering Centrifuges with Sludge Thickening Centrifuges",
  "image" : {
    "@type" : "ImageObject",
    "height" : 396,
    "url" : "https://4299619.fs1.hubspotusercontent-na1.net/hubfs/4299619/CaseStudy-City-of-Wyoming-MI-THK350.png",
    "width" : 704
  },
  "mainEntityOfPage" : "https://www.centrisys-cnp.com/case-studies/plant-replaces-modified-dewatering-centrifuges-with-sludge-thickening-centrifuges",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60,
      "url" : "/hs/hsstatic/content_shared_assets/static-1.4092/img/default-amp-logo.png",
      "width" : 60
    },
    "name" : "Case Studies"
  }
}
```